Kinetics Noise Control
Home > Noise Control Building Materials > STC/IIC Sound Test Reports > Concrete Structural Deck > Above and Below Deck
KINETICS®

STC/IIC Sound Test Data, Above and Below Concrete Structural Deck

Description STC IIC Sections Test #
6" Concrete Slab 53 27 AT001049
Requires Adobe Reader
4" Concrete Slab
1/2" Plywood
2" KINETICS RIM-Q-2-16
6" Concrete Slab
KINETICS ICC Isolation Hanger
Cold Rolled Channel (CRC)
Drywall Furring Channel
3-1/2" Fiberglass Insulation
2 Layers 5/8" Gypsum Board
94 82 AT001031
Requires Adobe Reader
Ceramic Tile
KINETICS ISOLayment QT Underlayment
6" Concrete Slab
KINETICS KSCH Spring Ceiling Hanger
Cold Rolled Channel (CRC)
Drywall Furring Channel
2" Fiberglass Insulation
3-3/8" Air Space
2 Layers 5/8" Gypsum Board
69 62 AT001112
Requires Adobe Reader
8" Flexicore Precast Subfloor   21 AT001070
Requires Adobe Reader
Ceramic Tile
7/16" Glass Mesh Mortar Unit/Bond Coat
5/8" KINETICS SR Floorboard
8" Flexicore Precast Subfloor
3-1/2" Fiberglass Fill in 10" Air Space
5/8" Gypsum Board on Resilient Channel
60 65 AT001039
Requires Adobe Reader