Description | STC | IIC | Sections | Test # |
---|---|---|---|---|
6" Concrete Slab | 53 | 27 | AT001049 |
|
2" Topping Slab Precast Concrete 14" Tee |
54 | 24 | AT001010 |
|
6" Concrete Slab KINETICS ICC Isolation Hanger Cold Rolled Channel (CRC) Drywall Furring Channel 3-1/2" Fiberglass Insulation 2 Layers 5/8" Gypsum Board |
84 | 70 | AT001032 |
|
6" Concrete Slab KINETICS KSCH-APB Spring Ceiling Hanger Cold Rolled Channel (CRC) Drywall Furring Channel 3-5/8" Fiberglass Insulation 12" Air Space 2 Layers 5/8" Gypsum Board |
81 | 60 | AT001114 |
|
6" Concrete Slab KINETICS KSCH-APB Spring Ceiling Hanger Cold Rolled Channel (CRC) Drywall Furring Channel 3-5/8" Fiberglass Insulation 8" Air Space 2 Layers 5/8" Gypsum Board |
80 | 64 | AT001113 |
|
6" Concrete Slab KINETICS KSCH Spring Ceiling Hanger Cold Rolled Channel (CRC) Drywall Furring Channel 1-1/2" Fiberglass Insulation 3-3/8" Air Space 2 Layers 5/8" Gypsum Board |
69 | 54 | AT001111 |
|
6" Concrete Slab KINETICS IsoGrid Ceiling Hanger 6" Airspace Filled with Fiberglass Insulation Cold Rolled Channel (CRC) Drywall Furring Channel 2 Layers 5/8" Gypsum Board |
63 | 50 | AT001084 |
|
6" Concrete Slab KINETICS IsoMax Clips 1-1/2" Drywall Furring Channel 2-1/2" Fiberglass Insulation compressed to 2" 5/8" Gypsum Board |
66 | 44 | AT001052 |