KINETICS® Below Concrete Structural Deck

STC/IIC Sound Test Data

Description STC IIC Sections Test #
6" Concrete Slab 53 27 AT001049
Requires Adobe Reader
2" Topping Slab
Precast Concrete 14" Tee
54 24 AT001010
Requires Adobe Reader
6" Concrete Slab
KINETICS ICC Isolation Hanger
Cold Rolled Channel (CRC)
Drywall Furring Channel
3-1/2" Fiberglass Insulation
2 Layers 5/8" Gypsum Board
84 70 AT001032
Requires Adobe Reader
6" Concrete Slab
KINETICS KSCH-APB Spring Ceiling Hanger
Cold Rolled Channel (CRC)
Drywall Furring Channel
3-5/8" Fiberglass Insulation
12" Air Space
2 Layers 5/8" Gypsum Board
81 60 AT001114
Requires Adobe Reader
6" Concrete Slab
KINETICS KSCH-APB Spring Ceiling Hanger
Cold Rolled Channel (CRC)
Drywall Furring Channel
3-5/8" Fiberglass Insulation
8" Air Space
2 Layers 5/8" Gypsum Board
80 64 AT001113
Requires Adobe Reader
6" Concrete Slab
KINETICS KSCH Spring Ceiling Hanger
Cold Rolled Channel (CRC)
Drywall Furring Channel
1-1/2" Fiberglass Insulation
3-3/8" Air Space
2 Layers 5/8" Gypsum Board
69 54 AT001111
Requires Adobe Reader
6" Concrete Slab
KINETICS IsoGrid Ceiling Hanger
6" Airspace Filled with Fiberglass Insulation
Cold Rolled Channel (CRC)
Drywall Furring Channel
2 Layers 5/8" Gypsum Board
63 50 AT001084
Requires Adobe Reader
6" Concrete Slab
KINETICS IsoMax Clips
1-1/2" Drywall Furring Channel
2-1/2" Fiberglass Insulation compressed to 2"
5/8" Gypsum Board
66 44 AT001052
Requires Adobe Reader