Kinetics Noise Control
Home > Noise Control Building Materials > IsoMax > STC/IIC Sound Test Data
KINETICS®

STC/IIC Sound Test Data | IsoMax Sound Isolation Clips

Description STC IIC Sections Test #
6" Concrete Slab 53 27 AT001049
Requires Adobe Reader
6" Concrete Slab
KINETICS IsoMax Clips
1-1/2" Drywall Furring Channel
2-1/2" Fiberglass Insulation compressed to 2"
5/8" Gypsum Board
66 44 AT001052
Requires Adobe Reader
Hardwood Floor with 1/8" Pad
Gypsum Concrete
3/4" Plywood
14" I-Joist
6" Fiberglass Insulation
2 Layers of 5/8" Gypsum Board
No Resilient Channel
51 39 AT001081
Requires Adobe Reader
Hardwood Floor with 1/8" Pad
1-1/4" Gypsum Concrete
3/4" Plywood
14" I-Joist
6" Fiberglass Insulation
KINETICS IsoMax Clips
7/8" Drywall Furring Channel
2 Layers of 5/8" Gypsum Board
54 57 AT001085
Requires Adobe Reader
Hardwood/Laminate Finish Floor
1-1/2" Gypsum Concrete
Acousti-Mat II Underlayment
13/16" Oriented Stand Board (OSB)
Blown-in Fiber Glass
18" I-Joist
2 Layers 5/8" Gypsum Board
FSTC 54 FIIC 45
AT001096A
AT001096
Requires Adobe Reader
Hardwood/Laminate Finish Floor
1-1/2" Gypsum Concrete
Acousti-Mat II Underlayment
13/16" Oriented Stand Board (OSB)
Blown-in Fiber Glass
18" I-Joist
KINETICS IsoMax Clips
7/8" Drywall Furring Channel
2 Layers 5/8" Gypsum Board
FSTC 61 FIIC 62
AT001096B
AT001096
Requires Adobe Reader
5/8" Gypsum Board
2x4 Wood Stud
Fiberglass Insulation
KINETICS IsoMax Clips
7/8" Drywall Furring Channel
5/8" Gypsum Board
57   AT001056
Requires Adobe Reader
5/8" Gypsum Board
2x4 Wood Stud
Fiberglass Insulation
KINETICS IsoMax Clips
7/8" Drywall Furring Channel
2 Layers of 5/8" Gypsum Board
61   AT001057
Requires Adobe Reader
2 Layers of 5/8" Gypsum Board
2x4 Wood Stud
Fiberglass Insulation
KINETICS IsoMax Clips
7/8" Drywall Furring Channel
2 Layers of 5/8" Gypsum Board
64   AT001058
Requires Adobe Reader
3 Layers of 5/8" Gypsum Board
2x6 Wood Stud
KINETICS IsoMax Clips
7/8" Drywall Furring Channel
2 Layers of 5/8" Gypsum Board
65   AT001090
Requires Adobe Reader
IsoMax Low Frequency Sound Transmission Loss (dB)
Kinetics Test Number Frequency (Hz)
31.5 40 50 63 80
AT001056 14 21 17 16 24
AT001057 16 22 20 23 30
AT001058 15 22 24 30 36
AT001090 14 24 32 39 38
Transmission Loss (TL) values were calculated at these additional test frequencies. Although the measurements were made in accordance with the procedures described in ASTM E90-99, they do not qualify as part of the standard. Since the results for these low frequencies are representative of the test environment only, they are unofficial and intended for research and development guidelines rather than for commercial purposes.
5/8" Gypsum Board
1-5/8" x 3-5/8" Steel Stud
Fiberglass Insulation
KINETICS IsoMax Clips
7/8" Drywall Furring Channel
2 Layers of 5/8" Gypsum Board
60   AT001072
Requires Adobe Reader
2 Layers of 5/8" Gypsum Board
1-5/8" x 3-5/8" Steel Stud
Fiberglass Insulation
KINETICS IsoMax Clips
7/8" Drywall Furring Channel
2 Layers of 5/8" Gypsum Board
63   AT001073
Requires Adobe Reader
5/8" Gypsum Board
2x4 Wood Stud
5/8" Gypsum Board
33   AT001089
Requires Adobe Reader
5/8" Gypsum Board
2x4 Wood Stud
5/8" Gypsum Board
KINETICS IsoMax Clips
1-1/2" Drywall Furring Channel
Fiberglass Insulation
5/8" Gypsum Board
46   Wall
Retrofit
AT001054
Requires Adobe Reader
5/8" Gypsum Board
2x4 Wood Stud
5/8" Gypsum Board
KINETICS IsoMax Clips
1-1/2" Drywall Furring Channel
Fiberglass Insulation
2 Layers of 5/8" Gypsum Board
52   Wall
Retrofit
AT001055
Requires Adobe Reader