Needing to construct a noise control ceiling below a noisy amenity space or maybe in a band room to keep noise out of classrooms on the next floor level? Properly selected ceiling hangers isolate from the structural decking a single layer or multiple layers of gypsum board and other materials used for constructing noise control ceilings. Using basic resilient elements (e.g., rubber pads, coil springs) to separate mass and create an airspace is an effective way to raise STC and IIC ratings, i.e., make an occupied space quieter. And when used in conjunction with floor isolation systems, ceilings suspended from resilient hangers offer optimal noise control between those noisy amenity spaces or equipment penthouses and the occupied spaces below. Kinetics offers a wide range of ceiling hangers to fit your design requirements including full performance, one-inch deflection spring hangers or simple resilient pad hangers.
Class
Full 1” Deflection Spring Hangers
Isolation Type: 1-inch Deflection Coil Spring
Capacity: 12-210 lbs
Fire Rating: UL L581
Seismic Zone Capable: A-F
Tested STC Range: 57-76
Tested IIC Range: 52-89
Grid Install Method: Cold Rolled Caddy
View ProductIsolation Type: 1-inch Deflection Coil Spring
Capacity: 12-210 lbs
Seismic Zone Capable: A-F
Tested STC Range: 84-94
Tested IIC Range: 70-82
Grid Install Method: Cold Rolled Caddy
View ProductIsolation Type: 1-inch Deflection Coil Spring
Capacity: 22-223 lbs
Seismic Zone Capable: A-F
Tested STC Range: 59-72
Tested IIC Range: 47-51
Grid Install Method: Internal Cold Rolled Space Saver
View ProductIsolation Type: 1-inch Deflection Coil Spring w/ Neoprene Element
Capacity: 12-370lbs
Seismic Zone Capable: A-B
Grid Install Method: Wire Tie
View ProductIsolation Type: 1-inch Deflection Coil Spring Neoprene Element
Capacity: 12-210 lbs
Seismic Zone Capable: A-B
Grid Install Method: Cold Rolled Caddy
View ProductClass
1/2” Deflection Spring Hangers
Isolation Type: 1/2-inch Deflection Leaf Spring/Underlayment System
Capacity: 22-44 lbs
Fire Rating: ICC-ESR 3207
Seismic Zone Capable: A-F
Tested STC Range: 60-61
Tested IIC Range: 56-57
Grid Install Method: Furring Channel Cradle
View ProductClass
Neoprene and Fiberglass Isolators
Isolation Type: Neoprene Element
Capacity: 36-60 lbs
Fire Rating: UL L583
Seismic Zone Capable: A-B
Tested STC Range: 54-66
Tested IIC Range: 44-58
Grid Install Method: Furring Clip
View ProductIsolation Type: Neoprene Element
Capacity: 40-160 lbs
Seismic Zone Capable: A-B
Tested STC Range: 63
Tested IIC Range: 50
Grid Install Method: Wire Tie
View ProductIsolation Type: Fiberglass Pad
Capacity: 100-200 lbs
Grid Install Method: Wire Tie
View Product