Testing Results


Sound Test- Lab #AT001049

6" Structural Slab

  • KINETICS NOISE CONTROL PRODUCTS:
    • NONE
  • ACOUSTICAL RATINGS:
    • STC 53
    • IIC 27
  • TESTING AGENCY & REPORT NUMBER:
    • NATIONAL RESEARCH COUNCIL OF CANADA
    • B-3463.1

Sound Test- Lab #AT001052

6" Structural Slab
IsoMax
1-1/2" Furring Channel
2-1/2" Fiberglass Insulation Compressed to 2"
5/8" Gypsum Board

  • KINETICS NOISE CONTROL PRODUCTS:
    • ISOMAX CLIPS
  • ACOUSTICAL RATINGS:
    • STC 66
    • IIC 44
  • TESTING AGENCY & REPORT NUMBER:
    • NATIONAL RESEARCH COUNCIL OF CANADA
    • B-3448.5

Sound Test- Lab #AT001054

5/8" Gypsum Board
2" x 4" Wood Stud Wall
Spaced 16" on Center
5/8" Gypsum Board
IsoMax
Fiberglass Insulation
5/8" Gypsum Board

  • KINETICS NOISE CONTROL PRODUCTS:
    • ISOMAX CLIPS
  • ACOUSTICAL RATINGS:
    • STC 46
  • TESTING AGENCY & REPORT NUMBER:
    • RIVERBANK ACOUSTICAL LABORATORIES
    • RAL TL04-278

Sound Test- Lab #AT001055

5/8" Gypsum Board
2" x 4" Wood Stud Wall
Spaced 16" on Center
5/8" Gypsum Board
IsoMax
Fiberglass Insulation
Drywall Furring Channel
2 Layers 5/8" Gypsum Board

  • KINETICS NOISE CONTROL PRODUCTS:
    • ISOMAX CLIPS
  • ACOUSTICAL RATINGS:
    • STC 52
  • TESTING AGENCY & REPORT NUMBER:
    • RIVERBANK ACOUSTICAL LABORATORIES
    • RAL TL04-279

Sound Test- Lab #AT001056

5/8" Gypsum Board
2" x 4" Wood Stud Wall
Spaced 16" on Center
Perimeter Sealant
IsoMax
Drywall Furring Channel
5/8" Gypsum Board

  • KINETICS NOISE CONTROL PRODUCTS:
    • ISOMAX CLIPS
  • ACOUSTICAL RATINGS:
    • STC 57
  • TESTING AGENCY & REPORT NUMBER:
    • RIVERBANK ACOUSTICAL LABORATORIES
    • RAL TL02-34

Sound Test- Lab #AT001057

5/8" Gypsum Board
2" x 4" Wood Stud Wall
Spaced 16" on Center
Perimeter Sealant
IsoMax
Drywall Furring Channel
2 Layers 5/8" Gypsum Board

  • KINETICS NOISE CONTROL PRODUCTS:
    • ISOMAX CLIPS
  • ACOUSTICAL RATINGS:
    • STC 61
    • IIC 27
  • TESTING AGENCY & REPORT NUMBER:
    • RIVERBANK ACOUSTICAL LABORATORIES
    • RAL TL02-35

Sound Test- Lab #AT001058

2 Layers 5/8" Gypsum Board
2" x 4" Wood Stud Wall
Spaced 16" on Center
Perimeter Sealant
IsoMax
Drywall Furring Channel
2 Layers 5/8" Gypsum Board

  • KINETICS NOISE CONTROL PRODUCTS:
    • ISOMAX CLIPS
  • ACOUSTICAL RATINGS:
    • STC 64
  • TESTING AGENCY & REPORT NUMBER:
    • RIVERBANK ACOUSTICAL LABORATORIES
    • RAL TL02-40

Sound Test- Lab #AT001072

5/8" Type X Drywall
R-19 Fiberglass
20 Guage, 3-5/8" Metal Studs
Perimeter Sealant
IsoMax
25 Gauge, 7/8" x 2-9/16" Furring Channel
2 Layers 5/8" Type X Drywall

  • KINETICS NOISE CONTROL PRODUCTS:
    • ISOMAX CLIPS
  • ACOUSTICAL RATINGS:
    • STC 60
  • TESTING AGENCY & REPORT NUMBER:
    • RIVERBANK ACOUSTICAL LABORATORIES
    • RAL TL06-025

Sound Test- Lab #AT001073

2 Layers 5/8" Type X Drywall
R-19 Fiberglass
20 Guage, 3-5/8" Metal Studs
Perimeter Sealant
IsoMax
25 Gauge, 7/8" x 2-9/16" Furring Channel
2 Layers 5/8" Type X Drywall

  • KINETICS NOISE CONTROL PRODUCTS:
    • ISOMAX CLIPS
  • ACOUSTICAL RATINGS:
    • STC 63
  • TESTING AGENCY & REPORT NUMBER:
    • RIVERBANK ACOUSTICAL LABORATORIES
    • RAL TL06-048

Sound Test- Lab #AT001081

Hardwood Floor and Pad
Gypcrete
3/4" Plywood
14" I-Joint
6" Fiberglass
2 Layers 5/8" Type X Drywall

  • KINETICS NOISE CONTROL PRODUCTS:
    • NONE
  • ACOUSTICAL RATINGS:
    • STC 51
    • IIC 39
  • TESTING AGENCY & REPORT NUMBER:
    • INTERTEK ETL SEMKO
    • 3103281 CRT-001G
    • 3103281 CRT-001H

Sound Test- Lab #AT001085

Hardwood Floor and Pad
1-1/4" Gypcrete
3/4" Plywood
14" I-Joint
Fiberglass
IsoMax
2 Layers 5/8" Type X Drywall

  • KINETICS NOISE CONTROL PRODUCTS:
    • ISOMAX
  • ACOUSTICAL RATINGS:
    • STC 54
    • IIC 57
  • TESTING AGENCY & REPORT NUMBER:
    • INTERTEK ETL SEMKO
    • 3103281 CRT-001I
    • 3103281 CRT-001J

Sound Test- Lab #AT001089

5/8" Gypsum Board
2" x 4" Wood Stud Wall
Spaced 16" on Center
5/8" Gypsum Board

  • KINETICS NOISE CONTROL PRODUCTS:
    • NONE
  • ACOUSTICAL RATINGS:
    • STC 33
  • TESTING AGENCY & REPORT NUMBER:
    • RIVERBANK ACOUSTICAL LABORATORIES
    • RAL TL04-277

Sound Test- Lab #AT001090

3 Layers 5/8" Gypsum Board
2" x 6" Timber Framing
Spaced 16" on Center
IsoMax Clip
7/8" Furring Channel
2 Layers 5/8" Gypsum Board

  • KINETICS NOISE CONTROL PRODUCTS:
    • ISOMAX CLIPS
  • ACOUSTICAL RATINGS:
    • STC 65
  • TESTING AGENCY & REPORT NUMBER:
    • RIVERBANK ACOUSTICAL LABORATORIES
    • RAL TL02-46

Sound Test- Field #AT001096A

Hardwood/Laminate Floor
1-1/2" Gyp-Crete
Acousti-Mat II Underlayment
13/16" OSB
14" I-Joint
Blown in Fiberglass
11-7/8" TJI Engineered Wood Joists
2 Layers 5/8" Type X Gypsum Board

  • KINETICS NOISE CONTROL PRODUCTS:
    • NONE
  • ACOUSTICAL RATINGS:
    • FSTC 54
    • FIIC 45
  • TESTING AGENCY & REPORT NUMBER:
    • FASZER FARQUHARSON & ASSOCIATES LTD.
    • FILE 106-1585-01

Sound Test- Field #AT001096B

Hardwood/Laminate Floor
1-1/2" Gyp-Crete
Acousti-Mat II Underlayment
13/16" OSB
14" I-Joint
Blown in Fiberglass
11-7/8" TJI Engineered Wood Joists
IsoMax Clip
7/8" Furring Channel
2 Layers 5/8" Type X Gypsum Board

  • KINETICS NOISE CONTROL PRODUCTS:
    • ISOMAX CLIPS
  • ACOUSTICAL RATINGS:
    • FSTC 61
    • FIIC 62
  • TESTING AGENCY & REPORT NUMBER:
    • FASZER FARQUHARSON & ASSOCIATES LTD.
    • FILE 106-1585-01


Submittal Documents


Click on image to enlarge. Download multiple files by checking orange boxes next to desired files then click EXPORT.

Testing


STC/IIC Sound Test Data

  • Sound Test- Lab #AT001049
  • 6" Structural Slab

STC/IIC Sound Test Data

  • Sound Test- Lab #AT001052
  • 6" Structural Slab
  • IsoMax
  • 1-1/2" Furring Channel
  • 2-1/2" Fiberglass Insulation Compressed to 2"
  • 5/8" Gypsum Board

STC/IIC Sound Test Data

  • Sound Test- Lab #AT001054
  • 5/8" Gypsum Board
  • 2" x 4" Wood Stud Wall
  • Spaced 16" on Center
  • 5/8" Gypsum Board
  • IsoMax
  • Fiberglass Insulation
  • 5/8" Gypsum Board

STC/IIC Sound Test Data

  • Sound Test- Lab #AT001055
  • 5/8" Gypsum Board
  • 2" x 4" Wood Stud Wall
  • Spaced 16" on Center
  • 5/8" Gypsum Board
  • IsoMax
  • Fiberglass Insulation
  • Drywall Furring Channel
  • 2 Layers 5/8" Gypsum Board

STC/IIC Sound Test Data

  • Sound Test- Lab #AT001056
  • 5/8" Gypsum Board
  • 2" x 4" Wood Stud Wall
  • Spaced 16" on Center
  • Perimeter Sealant
  • IsoMax
  • Drywall Furring Channel
  • 5/8" Gypsum Board

STC/IIC Sound Test Data

  • Sound Test- Lab #AT001057
  • 5/8" Gypsum Board
  • 2" x 4" Wood Stud Wall
  • Spaced 16" on Center
  • Perimeter Sealant
  • IsoMax
  • Drywall Furring Channel
  • 2 Layers 5/8" Gypsum Board

STC/IIC Sound Test Data

  • Sound Test- Lab #AT001058
  • 2 Layers 5/8" Gypsum Board
  • 2" x 4" Wood Stud Wall
  • Spaced 16" on Center
  • Perimeter Sealant
  • IsoMax
  • Drywall Furring Channel
  • 2 Layers 5/8" Gypsum Board

STC/IIC Sound Test Data

  • Sound Test- Lab #AT001072
  • 5/8" Type X Drywall
  • R-19 Fiberglass
  • 20 Guage, 3-5/8" Metal Studs
  • Perimeter Sealant
  • IsoMax
  • 25 Gauge, 7/8" x 2-9/16" Furring Channel
  • 2 Layers 5/8" Type X Drywall

STC/IIC Sound Test Data

  • Sound Test- Lab #AT001073
  • 2 Layers 5/8" Type X Drywall
  • R-19 Fiberglass
  • 20 Guage, 3-5/8" Metal Studs
  • Perimeter Sealant
  • IsoMax
  • 25 Gauge, 7/8" x 2-9/16" Furring Channel
  • 2 Layers 5/8" Type X Drywall

STC/IIC Sound Test Data

  • Sound Test- Lab #AT001081
  • Hardwood Floor and Pad<
  • Gypcrete
  • 3/4" Plywood
  • 14" I-Joint
  • 6" Fiberglass
  • 2 Layers 5/8" Type X Drywall

STC/IIC Sound Test Data

  • Sound Test- Lab #AT001085
  • Hardwood Floor and Pad
  • 1-1/4" Gypcrete
  • 3/4" Plywood
  • 14" I-Joint
  • Fiberglass
  • IsoMax
  • 2 Layers 5/8" Type X Drywall

STC/IIC Sound Test Data

  • Sound Test- Lab #AT001089
  • 5/8" Gypsum Board
  • 2" x 4" Wood Stud Wall
  • Spaced 16" on Center
  • 5/8" Gypsum Board

STC/IIC Sound Test Data

  • Sound Test- Lab #AT001090
  • 3 Layers 5/8" Gypsum Board
  • 2" x 6" Timber Framing
  • Spaced 16" on Center
  • IsoMax Clip
  • 7/8" Furring Channel
  • 2 Layers 5/8" Gypsum Board

STC/IIC Sound Test Data

  • Sound Test- Field #AT001096A
  • Hardwood/Laminate Floor
  • 1-1/2" Gyp-Crete
  • Acousti-Mat II Underlayment
  • 13/16" OSB
  • 14" I-Joint
  • Blown in Fiberglass
  • 11-7/8" TJI Engineered Wood Joists
  • 2 Layers 5/8" Type X Gypsum Board

STC/IIC Sound Test Data

  • Sound Test- Field #AT001096B
  • Hardwood/Laminate Floor
  • 1-1/2" Gyp-Crete
  • Acousti-Mat II Underlayment
  • 13/16" OSB
  • 14" I-Joint
  • Blown in Fiberglass
  • 11-7/8" TJI Engineered Wood Joists
  • IsoMax Clip
  • 7/8" Furring Channel
  • 2 Layers 5/8" Type X Gypsum Board

System Components


RESILIENT INTERFACE (CPT)

SEALANT


Drawings


Submittal Drawing

Section View At Door Casing

Isolated Ceilings

Isolated Ceilings and Walls

Isolated Walls

Plan View Wall Intersections

Wall Elevation w/ Furring Channel

Ceiling Layout w/ Furring Channel

Furring Channel

Furring Channel w/ Clip Isolator


Additional Documents


DATA SHEET

SPECIFICATIONS

INSTALLATION

LEED

WARRANTY



Installation Guidelines


Installation Guidelines



Design Guidelines


TV Mount Isolation

Hand Rail Isolation

Fire Rated Ceiling Assemblies Comparison


KWSB2


KWSB2 Submittal

KWSB2 Installation

IsoMax clip resiliently secures common drywall furring channel Offering significantly higher STC values than drywall attached to resilient channel, IsoMax ensures that installers will not inadvertently screw through the “resilient” leg of the channel into the joist or stud.

Patent No. 7,093,814

The IsoMax Advantage

  • Low cost for high performance
  • Flexible “snap-on” clips install quickly, no pinching channel and allows for height adjustments during installation of channel
  • Error free installation of standard drywall furring channel. Eliminates accidental short circuiting common with resilient channel
  • Easiest method for STC 55+ stud wall assemblies
  • Can accommodate furring channel widths from 2.38" - 2.75"

UL Fire Ratings

  • IsoMax is featured in UL Design No. L583, a fire rated assembly for engineered joists, parallel chord trusses, and wood joists.
  • To view, visit UL Product iQ.
  • You will need to sign up for a free account.
  • Search for Kinetics Noise Control.
  • The results will display links to Kinetics UL rated designs.