IsoMax™

Sound Isolation Clips for Walls & Ceilings

Request A Quote

Low Cost, Space Saving Walls and Ceilings
Walls- Double stud wall noise control performance in less space at a lower cost
Ceilings- Achieve the performance of properly installed resilient channel

Resources


Drawings | BIM


BIM OBJECT

ZIP

Section View At Door Casing

PDF

Isolated Ceilings

PDF

Isolated Ceilings and Walls

PDF

Isolated Walls

PDF

Plan View Wall Intersections

PDF

Wall Elevation w/ Furring Channel

PDF

Ceiling Layout w/ Furring Channel

PDF

Furring Channel

PDF

Furring Channel w/ Clip Isolator

PDF

IsoMax Clip Installation

PDF



Testing Results


VOC/CDPH CERTIFICATE


Sound Test- Lab #AT001049

6" Structural Slab

  • KINETICS NOISE CONTROL PRODUCTS:
    • NONE
  • ACOUSTICAL RATINGS:
    • STC 53
    • IIC 27
  • TESTING AGENCY & REPORT NUMBER:
    • NATIONAL RESEARCH COUNCIL OF CANADA
    • B-3463.1

Sound Test- Lab #AT001052

6" Structural Slab
IsoMax
1-1/2" Furring Channel
2-1/2" Fiberglass Insulation Compressed to 2"
5/8" Gypsum Board

  • KINETICS NOISE CONTROL PRODUCTS:
    • ISOMAX CLIPS
  • ACOUSTICAL RATINGS:
    • STC 66
    • IIC 44
  • TESTING AGENCY & REPORT NUMBER:
    • NATIONAL RESEARCH COUNCIL OF CANADA
    • B-3448.5

Sound Test- Lab #AT001054

5/8" Gypsum Board
2" x 4" Wood Stud Wall
Spaced 16" on Center
5/8" Gypsum Board
IsoMax
Fiberglass Insulation
5/8" Gypsum Board

  • KINETICS NOISE CONTROL PRODUCTS:
    • ISOMAX CLIPS
  • ACOUSTICAL RATINGS:
    • STC 46
  • TESTING AGENCY & REPORT NUMBER:
    • RIVERBANK ACOUSTICAL LABORATORIES
    • RAL TL04-278

Sound Test- Lab #AT001055

5/8" Gypsum Board
2" x 4" Wood Stud Wall
Spaced 16" on Center
5/8" Gypsum Board
IsoMax
Fiberglass Insulation
Drywall Furring Channel
2 Layers 5/8" Gypsum Board

  • KINETICS NOISE CONTROL PRODUCTS:
    • ISOMAX CLIPS
  • ACOUSTICAL RATINGS:
    • STC 52
  • TESTING AGENCY & REPORT NUMBER:
    • RIVERBANK ACOUSTICAL LABORATORIES
    • RAL TL04-279

Sound Test- Lab #AT001056

5/8" Gypsum Board
2" x 4" Wood Stud Wall
Spaced 16" on Center
Perimeter Sealant
IsoMax
Drywall Furring Channel
5/8" Gypsum Board

  • KINETICS NOISE CONTROL PRODUCTS:
    • ISOMAX CLIPS
  • ACOUSTICAL RATINGS:
    • STC 57
  • TESTING AGENCY & REPORT NUMBER:
    • RIVERBANK ACOUSTICAL LABORATORIES
    • RAL TL02-34

Sound Test- Lab #AT001057

5/8" Gypsum Board
2" x 4" Wood Stud Wall
Spaced 16" on Center
Perimeter Sealant
IsoMax
Drywall Furring Channel
2 Layers 5/8" Gypsum Board

  • KINETICS NOISE CONTROL PRODUCTS:
    • ISOMAX CLIPS
  • ACOUSTICAL RATINGS:
    • STC 61
  • TESTING AGENCY & REPORT NUMBER:
    • RIVERBANK ACOUSTICAL LABORATORIES
    • RAL TL02-35

Sound Test- Lab #AT001058

2 Layers 5/8" Gypsum Board
2" x 4" Wood Stud Wall
Spaced 16" on Center
Perimeter Sealant
IsoMax
Drywall Furring Channel
2 Layers 5/8" Gypsum Board

  • KINETICS NOISE CONTROL PRODUCTS:
    • ISOMAX CLIPS
  • ACOUSTICAL RATINGS:
    • STC 64
  • TESTING AGENCY & REPORT NUMBER:
    • RIVERBANK ACOUSTICAL LABORATORIES
    • RAL TL02-40

Sound Test- Lab #AT001072

5/8" Type X Drywall
R-19 Fiberglass
20 Guage, 3-5/8" Metal Studs
Perimeter Sealant
IsoMax
25 Gauge, 7/8" x 2-9/16" Furring Channel
2 Layers 5/8" Type X Drywall

  • KINETICS NOISE CONTROL PRODUCTS:
    • ISOMAX CLIPS
  • ACOUSTICAL RATINGS:
    • STC 60
  • TESTING AGENCY & REPORT NUMBER:
    • RIVERBANK ACOUSTICAL LABORATORIES
    • RAL TL06-025

Sound Test- Lab #AT001073

2 Layers 5/8" Type X Drywall
R-19 Fiberglass
20 Guage, 3-5/8" Metal Studs
Perimeter Sealant
IsoMax
25 Gauge, 7/8" x 2-9/16" Furring Channel
2 Layers 5/8" Type X Drywall

  • KINETICS NOISE CONTROL PRODUCTS:
    • ISOMAX CLIPS
  • ACOUSTICAL RATINGS:
    • STC 63
  • TESTING AGENCY & REPORT NUMBER:
    • RIVERBANK ACOUSTICAL LABORATORIES
    • RAL TL06-048

Sound Test- Lab #AT001081

Hardwood Floor and Pad
Gypcrete
3/4" Plywood
14" I-Joint
6" Fiberglass
2 Layers 5/8" Type X Drywall

  • KINETICS NOISE CONTROL PRODUCTS:
    • NONE
  • ACOUSTICAL RATINGS:
    • STC 51
    • IIC 39
  • TESTING AGENCY & REPORT NUMBER:
    • INTERTEK ETL SEMKO
    • 3103281 CRT-001G
    • 3103281 CRT-001H

Sound Test- Lab #AT001085

Hardwood Floor and Pad
1-1/4" Gypcrete
3/4" Plywood
14" I-Joint
Fiberglass
IsoMax
2 Layers 5/8" Type X Drywall

  • KINETICS NOISE CONTROL PRODUCTS:
    • ISOMAX
  • ACOUSTICAL RATINGS:
    • STC 54
    • IIC 57
  • TESTING AGENCY & REPORT NUMBER:
    • INTERTEK ETL SEMKO
    • 3103281 CRT-001I
    • 3103281 CRT-001J

Sound Test- Lab #AT001089

5/8" Gypsum Board
2" x 4" Wood Stud Wall
Spaced 16" on Center
5/8" Gypsum Board

  • KINETICS NOISE CONTROL PRODUCTS:
    • NONE
  • ACOUSTICAL RATINGS:
    • STC 33
  • TESTING AGENCY & REPORT NUMBER:
    • RIVERBANK ACOUSTICAL LABORATORIES
    • RAL TL04-277

Sound Test- Lab #AT001090

3 Layers 5/8" Gypsum Board
2" x 6" Timber Framing
Spaced 16" on Center
IsoMax Clip
7/8" Furring Channel
2 Layers 5/8" Gypsum Board

  • KINETICS NOISE CONTROL PRODUCTS:
    • ISOMAX CLIPS
  • ACOUSTICAL RATINGS:
    • STC 65
  • TESTING AGENCY & REPORT NUMBER:
    • RIVERBANK ACOUSTICAL LABORATORIES
    • RAL TL02-46

Sound Test- Field #AT001096A

Hardwood/Laminate Floor
1-1/2" Gyp-Crete
Acousti-Mat II Underlayment
13/16" OSB
14" I-Joint
Blown in Fiberglass
11-7/8" TJI Engineered Wood Joists
2 Layers 5/8" Type X Gypsum Board

  • KINETICS NOISE CONTROL PRODUCTS:
    • NONE
  • ACOUSTICAL RATINGS:
    • FSTC 54
    • FIIC 45
  • TESTING AGENCY & REPORT NUMBER:
    • FASZER FARQUHARSON & ASSOCIATES LTD.
    • FILE 106-1585-01

Sound Test- Field #AT001096B

Hardwood/Laminate Floor
1-1/2" Gyp-Crete
Acousti-Mat II Underlayment
13/16" OSB
14" I-Joint
Blown in Fiberglass
11-7/8" TJI Engineered Wood Joists
IsoMax Clip
7/8" Furring Channel
2 Layers 5/8" Type X Gypsum Board

  • KINETICS NOISE CONTROL PRODUCTS:
    • ISOMAX CLIPS
  • ACOUSTICAL RATINGS:
    • FSTC 61
    • FIIC 62
  • TESTING AGENCY & REPORT NUMBER:
    • FASZER FARQUHARSON & ASSOCIATES LTD.
    • FILE 106-1585-01


Submittal Documents


Click on image to enlarge. Download multiple files by checking orange boxes next to desired files then click EXPORT.

Testing


STC/IIC Sound Test Data

  • Sound Test- Lab #AT001049
  • 6" Structural Slab

STC/IIC Sound Test Data

  • Sound Test- Lab #AT001052
  • 6" Structural Slab
  • IsoMax
  • 1-1/2" Furring Channel
  • 2-1/2" Fiberglass Insulation Compressed to 2"
  • 5/8" Gypsum Board

STC/IIC Sound Test Data

  • Sound Test- Lab #AT001054
  • 5/8" Gypsum Board
  • 2" x 4" Wood Stud Wall
  • Spaced 16" on Center
  • 5/8" Gypsum Board
  • IsoMax
  • Fiberglass Insulation
  • 5/8" Gypsum Board

STC/IIC Sound Test Data

  • Sound Test- Lab #AT001055
  • 5/8" Gypsum Board
  • 2" x 4" Wood Stud Wall
  • Spaced 16" on Center
  • 5/8" Gypsum Board
  • IsoMax
  • Fiberglass Insulation
  • Drywall Furring Channel
  • 2 Layers 5/8" Gypsum Board

STC/IIC Sound Test Data

  • Sound Test- Lab #AT001056
  • 5/8" Gypsum Board
  • 2" x 4" Wood Stud Wall
  • Spaced 16" on Center
  • Perimeter Sealant
  • IsoMax
  • Drywall Furring Channel
  • 5/8" Gypsum Board

STC/IIC Sound Test Data

  • Sound Test- Lab #AT001057
  • 5/8" Gypsum Board
  • 2" x 4" Wood Stud Wall
  • Spaced 16" on Center
  • Perimeter Sealant
  • IsoMax
  • Drywall Furring Channel
  • 2 Layers 5/8" Gypsum Board

STC/IIC Sound Test Data

  • Sound Test- Lab #AT001058
  • 2 Layers 5/8" Gypsum Board
  • 2" x 4" Wood Stud Wall
  • Spaced 16" on Center
  • Perimeter Sealant
  • IsoMax
  • Drywall Furring Channel
  • 2 Layers 5/8" Gypsum Board

STC/IIC Sound Test Data

  • Sound Test- Lab #AT001072
  • 5/8" Type X Drywall
  • R-19 Fiberglass
  • 20 Guage, 3-5/8" Metal Studs
  • Perimeter Sealant
  • IsoMax
  • 25 Gauge, 7/8" x 2-9/16" Furring Channel
  • 2 Layers 5/8" Type X Drywall

STC/IIC Sound Test Data

  • Sound Test- Lab #AT001073
  • 2 Layers 5/8" Type X Drywall
  • R-19 Fiberglass
  • 20 Guage, 3-5/8" Metal Studs
  • Perimeter Sealant
  • IsoMax
  • 25 Gauge, 7/8" x 2-9/16" Furring Channel
  • 2 Layers 5/8" Type X Drywall

STC/IIC Sound Test Data

  • Sound Test- Lab #AT001081
  • Hardwood Floor and Pad<
  • Gypcrete
  • 3/4" Plywood
  • 14" I-Joint
  • 6" Fiberglass
  • 2 Layers 5/8" Type X Drywall

STC/IIC Sound Test Data

  • Sound Test- Lab #AT001085
  • Hardwood Floor and Pad
  • 1-1/4" Gypcrete
  • 3/4" Plywood
  • 14" I-Joint
  • Fiberglass
  • IsoMax
  • 2 Layers 5/8" Type X Drywall

STC/IIC Sound Test Data

  • Sound Test- Lab #AT001089
  • 5/8" Gypsum Board
  • 2" x 4" Wood Stud Wall
  • Spaced 16" on Center
  • 5/8" Gypsum Board

STC/IIC Sound Test Data

  • Sound Test- Lab #AT001090
  • 3 Layers 5/8" Gypsum Board
  • 2" x 6" Timber Framing
  • Spaced 16" on Center
  • IsoMax Clip
  • 7/8" Furring Channel
  • 2 Layers 5/8" Gypsum Board

STC/IIC Sound Test Data

  • Sound Test- Field #AT001096A
  • Hardwood/Laminate Floor
  • 1-1/2" Gyp-Crete
  • Acousti-Mat II Underlayment
  • 13/16" OSB
  • 14" I-Joint
  • Blown in Fiberglass
  • 11-7/8" TJI Engineered Wood Joists
  • 2 Layers 5/8" Type X Gypsum Board

STC/IIC Sound Test Data

  • Sound Test- Field #AT001096B
  • Hardwood/Laminate Floor
  • 1-1/2" Gyp-Crete
  • Acousti-Mat II Underlayment
  • 13/16" OSB
  • 14" I-Joint
  • Blown in Fiberglass
  • 11-7/8" TJI Engineered Wood Joists
  • IsoMax Clip
  • 7/8" Furring Channel
  • 2 Layers 5/8" Type X Gypsum Board

System Components


RESILIENT INTERFACE (CPT)

SEALANT


Drawings


Submittal Drawing

Section View At Door Casing

Isolated Ceilings

Isolated Ceilings and Walls

Isolated Walls

Plan View Wall Intersections

Wall Elevation w/ Furring Channel

Ceiling Layout w/ Furring Channel

Furring Channel

Furring Channel w/ Clip Isolator


Additional Documents


DATA SHEET

BROCHURE

VOC/CDPH CERTIFICATE

SPECIFICATIONS

INSTALLATION

INSTALLATION (Spanish)

LEED

WARRANTY



Installation Guidelines


Installation Animation

Installation Guidelines

PDF

Installation Guidelines (Spanish)

PDF


Design Guidelines


TV Mount Isolation

Hand Rail Isolation

Fire Rated Ceiling Assemblies Comparison


KWSB2


KWSB2 Submittal

KWSB2 Installation

Designers wanting low-cost, space-saving ceilings and walls that provide superior noise control employ Kinetics IsoMax Sound Isolation Clips. Offering significantly higher STC values than drywall attached to resilient channel, IsoMax ensures that installers will not inadvertently screw through the “resilient” leg of the channel into the joist or stud. This feature cannot be underestimated given the frequent, unknown occurrences where resilient channel is accidentally rendered ineffective because it is hard-attached.

Patent No. 7,093,814

The IsoMax Advantage

  • Save labor with IsoMax!
  • Flexible snap or slide-on clips install quickly, allowing for height adjustments during installation of channel
  • Error free installation of standard drywall furring channel
  • Eliminates accidental short-circuiting common with resilient channel
  • Low profile design; maximizes available occupied space
  • Low cost for high performance
  • Preferred choice for acoustical performance
  • Can accommodate furring channel widths from 2.38" - 2.75"

Additional Features

  • Completely engulfs furring channel preventing rattling that comes from metal-to-metal connections, which is common using other isolation clips.
  • Bends to allow the clip to adapt and accept all common-sized furring channel
  • Easier installation
    • Multiple simple methods to install IsoMax
    • No need to pinch furring channel to fit in IsoMax
    • IsoMax does not need to be dead level to accept furring channel

UL Fire Ratings

Design No. L583

Floor/Ceiling Assembly allows the broadest range of joist or truss assemblies including: engineered “I” joists, wood and steel trusses, 2 x 10 sawn wood joists, and parallel chord trusses.

Allows fiberglass or mineral wool insulation with two (2) layers of gypsum wallboard.

Ceilings
Design No. L546
Design No. V477
Design No. V489
Walls
Design No. U305
Design No. U419
  • To view complete reports, visit UL Product IQ
  • You will need to sign up for a free account.
  • Search for Kinetics Noise Control.
  • The results will display links to Kinetics UL rated designs.