Wallmat

Stud Wall Isolator

Request A Quote

Kinetics Wallmat stud wall isolator is a molded fiberglass mat which resiliently decouples a sound-rated wall from non-isolated structure. Isolation is ensured with the use of KAI anchor isolators which keeps fasteners decoupled from the framing. Apply Wallmat continuously along the bottom and top plates of a stud wall wherever acoustical isolation is required to reduce flanking and maintain a fully effective sound-rated assembly. Wallmat may be customized for your special project requirements.

Resources


Drawings | BIM


Submittal Drawing- Wallmat

Submittal Drawing- Wallmat

PDF

DWG

Submittal Drawing-1/4" KAI (Steel)

PDF

DWG

Steel-Framed Installation 1/4"

PDF

DWG

Submittal Drawing-1/4" KAI (Wood)

PDF

DWG

Wood-Framed Installation 1/4"

PDF

DWG

Steel-Framed Installation 3/8"

PDF

DWG

Wood-Framed Installation 3/8"

PDF

DWG

Top of Wall Detail with 3/8" Anchors

PDF

DWG



Testing Results


UL Rated Joint System- Double Stud

Tongue & Groove Wood Flooring
4" Isolated Concrete Slab
LSM with 2" Air Space (vented)
6" Structural Slab

  • KINETICS NOISE CONTROL PRODUCTS:
    • Wallmat

UL Rated Joint System- Single Stud

Shredded Rubber Flooring
4" Isolated Concrete Slab
LSM with 2" Air Space (vented)
6" Structural Slab

  • KINETICS NOISE CONTROL PRODUCTS:
    • Wallmat


Submittal Documents


Click on image to enlarge. Download multiple files by checking orange boxes next to desired files then click EXPORT.

Testing


STC/IIC Sound Test Data

  • UL Rated Joint System- Double Stud
  • Tongue & Groove Wood Flooring
  • 4" Isolated Concrete Slab
  • 2" Air Space (vented)
  • 6" Structural Slab

STC/IIC Sound Test Data

  • UL Rated Joint System- Single Stud
  • Shredded Rubber Flooring
  • 4" Isolated Concrete Slab
  • 2" Air Space (vented)
  • 6" Structural Slab

System Components


SEALANT


Drawings


Submittal Drawing- Wallmat

Submittal Drawing-3/8" KAI

Submittal Drawing-1/4" KAI (Steel)

Steel-Framed Installation 1/4"

Submittal Drawing-1/4" KAI (Wood)

Wood-Framed Installation 1/4"

Steel-Framed Installation 3/8"

Wood-Framed Installation 3/8"

Top of Wall Detail at Corrugated Metal Deck


Additional Documents


DATA SHEET

Specifications

LEED

WARRANTY



Design Guidelines


UL Rated Joint System- Double Stud

UL Rated Joint System- Single Stud


Related Products


Flanking of sound through a floor/ceiling assembly can reduce STC (airborne noise) or IIC (impact noise) ratings 10 points or more versus non-flanked sound control construction. Frequently used in conjunction with other Kinetics sound isolation products, Wallmat creates a resilient break to stop sound or vibration from flanking around a sound rated assembly. Rubber bushing assemblies (KAI) used at each anchor point through the top and bottom plates of the stud wall ensure effective isolation.

Uses Kinetics’s KIP Isolator technology

Easy to install 48" long pre-cut mats

Available in standard widths, 3" and 5"

Special widths as required for your project; optional coating available for wet area installations – ask for prices

Continuous resilient support of the partition

Engineered for a wide range of stud wall loads

Use KAI anchor isolators for 100% resilient separation

Use for both top and bottom plate installation

Can be used in UL Rated assemblies

REQUEST A QUOTE